Tri Band Power Amplifier and Signal Generator Module Customized Frequency and Power DDS ALC RACK Version with Touch Screen
ZD-1UDPA-950/2.4/5.2-100W
This rack-mounted three-band power amplifier and signal generator module ,the operating frequency can be customized, the power is 100W, the voltage is 28V, the conversion efficiency is ≥42% (at 100W), the output power is 10W - 100W software adjustable, the ALC power adjustment range is ≥20dB, the gain is 50±1.0dB, the in-band fluctuation is ≤2.5dB, and the spurious emission is low. It has rich monitoring functions, and can set parameters such as amplifier switch and alarm, and detect power, standing wave ratio, temperature, etc. in real time. Through RS485 communication, there are three frequency setting modes, and the touch screen is easy to operate, providing stable and reliable signal amplification and generation for jammer applications.
Quantity:
This high-performance tri band power amplifierintegrated with signal generatormodule is a customizable RF solution designed for professional communication and electronic systems. Supporting customizable working frequencies and delivering up to 100W output power, this tri band power amplifierfeatures adjustable 10W~100W software-controlled power, ≥20dB ALC power adjustment range, and 50±1.0dB gain with ≤2.5dB in-band fluctuation, ensuring stable and uniform signal output.
Equipped with DDS and ALC technologies, it offers excellent spurious emissions control (≤-15dBm/1MHz in-band) and wide operating temperature range (-10~+65℃) with reliable gain/power stability. The rack-mounted version with a touch screen includes comprehensive monitoring functions: power control, over-temperature/over-power/over-current/over-voltage alarms, and real-time output power detection. With 28V operating voltage, N-Female RF connector, and RS485 communication interface, this signal generatorintegrated amplifier module is ideal for multi-band RF systems, electronic countermeasures, and communication relay applications, providing flexible, reliable, and intelligent RF signal amplification solutions.
| Item | Parameter | Remark | |||
| working frequency | customizable | ||||
| power | 100W | ||||
| Operating Voltage | 28V | 24-36V | |||
| Conversion efficiency | ≥42% | @100W | |||
| Adjustable output power | 10W~100W | Software set power | |||
| ALC power adjustment range | ≥20dB | Voltage Controlled Attenuation | |||
| gain | 50±1.0dB | ||||
| In-band fluctuation | ≤2.5dB | peak | |||
| spurious emissions | In working band | ≤-15dBm/1MHz | Measured when the center frequency plus CW signal to the maximum output power | ||
| Out-of-band | 9KHz~1GHz | No higher than normal noise floor clutter | |||
| 1G~12.75GHz | |||||
| Maximum allowable input power | ≥+10dBm | Lasts 1min without damage | |||
| Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | |||
| Output VSWR | ≤1.35 | No power, standard network output -10dBm | |||
| ≤1.35 | Power On, Dual Directional Coupler Test | ||||
| High and low temperature test | Working environment temperature (℃) | -10~+65℃ | Low temperature can start, monitoring works normally | ||
| Gain Stability | ±1.5dB @-40℃~+65℃ | ||||
| power stability | ±1dB @-40℃~+65℃ | ||||
| Power Requirements | ≥8.5A @+28Vdc; | CW output 100W | |||
| Power supply interface, communication interface RS485 | 7W2 | Male, 1:485A; 2:485B | |||
| RF output connector | N-Female connector | ||||
| with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | ||||
| physical dimension | |||||
| weight | |||||
| Appearance (how to use) | Signal source power amplifier integrated module (fixed on the radiator) | ||||
| Monitoring Function | Description | Remark | |
| Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
| Alarm switch | Enable and disable the alarm function | ||
| Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
| Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
| Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
| Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
| Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
| Amplifier under-power alarm | When the power amplifier detection power is less than 33dBm, an under-power alarm is displayed | ||
| Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
| Amplifier undervoltage alarm | Amplifier voltage | ||
| Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to"OFF", the query should be the state of power amplifier off state; otherwise, it is the open power amplifier state | |
| Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy: Pout±1dB | |
| Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
| temperature query | Detect the internal temperature of the module, detection range: -40℃~+100℃ | Detection error: ±3℃ | |
| ALC value query | The displayed value is equal to the actual set ALC value | ||
| Voltage detection | Detection module working voltage | ||
| Current Detection | Detection module operating current | ||
| Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
| Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
| Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and the sub-segments are incremented | ||
| Module Communication Protocol | RS485 | ||
| Interface definition | +:28V,-: GND; 1:485A,2:485B | ||