0
image
image
image
image
signal generator

Power Amplifier with Signal Generator DDS ALC Touch Screen Rack Version

ZD-1UDPA-2399/2503M-100W
Single band power amplifier and Signal generator module customized frequency and power DDS ALC RACK version ,the working frequency 2399 - 2503M, power 100W, voltage 28V, conversion efficiency ≥42% (at 100W), output power 10W - 100W software adjustable, ALC adjustment range ≥20dB, gain 50±1.0dB. It has low spurious emission and multiple alarm protection functions. Through touch screen operation, frequency and other parameters can be set. It adopts N-type female connector, rack design, working temperature -10℃ - +65℃, meeting the signal processing needs of professional fields.
Quantity:
Contact Now
add to cart
In professional security, facility protection and signal management scenarios, precise control over specific frequency band signals is essential. Thissingle band power amplifierwith integratedsignal generator modulefeatures customizable frequency and power, and comes as aDDS&ALCenabled rack-mounted version with a user-friendly touch screen. Operating at 2399–2503MHz with up to 100W output, it offers 50±1.0dB gain, ≤2.5dB in-band flatness andALCadjustment range ≥20dB, ensuring stable and clean signal transmission.
Powered by 24–36V DC with efficiency ≥42%, its output can be software-tuned from 10W to 100W. Superior in-band spurious suppression ≤-15dBm/1MHz minimizes interference. Equipped with comprehensive intelligent protection including over-temperature, over-voltage and VSWR alarms, it supports real-time parameter monitoring and automatic shutdown/recovery. The rack-mounted chassis, N-type RF port and intuitive touch screen operation make installation and control highly convenient. With a wide operating temperature range of -10℃ to +65℃, thissingle band power amplifierwithDDS&ALCtechnology delivers reliable performance for various professional signal control applications.
 
ItemParameterRemark
working frequency2399-2503M
power100W
Operating Voltage28V24-36V
Conversion efficiency≥42%@100W
Adjustable output power10W~100WSoftware set power
ALC power adjustment range≥20dBVoltage Controlled Attenuation
gain50±1.0dB
In-band fluctuation≤2.5dBpeak
spurious emissionsIn working band≤-15dBm/1MHzMeasured when the center frequency plus CW signal to the maximum output power
Out-of-band9KHz~1GHzNo higher than normal noise floor clutter
1G~12.75GHz
Maximum allowable input power≥+10dBmLasts 1min without damage
Input VSWR≤1.35Add +28V, standard network output -10dBm
Output VSWR≤1.35No power, standard network output -10dBm
≤1.35Power On, Dual Directional Coupler Test
High and low temperature testWorking environment temperature (℃)-10~+65℃Low temperature can start, monitoring works normally
Gain Stability±1.5dB @-40℃~+65℃
power stability±1dB @-40℃~+65℃
Power Requirements≥8.5A @+28Vdc;CW output 100W
Power supply interface, communication interface RS4857W2Male, 1:485A; 2:485B
RF output connectorN-Female connector
with 3 LED lightsPOWER: Power indication; RUN: Running indication; ALARM: Alarm indication;
physical dimension
weight
Appearance (how to use)Signal source power amplifier integrated module (fixed on the radiator)
Monitoring FunctionDescriptionRemark
Amplifier part setting parametersAmplifier switchTurn the amplifier on or off
Alarm switchEnable and disable the alarm function
Downlink Power ControlThe maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power
levels can be set
Amplifier over temperature alarmThe high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will
automatically shut down; 65 degrees will automatically restore
Amplifier overpower alarmThe actual power value is 2dB higher than the downlink ALC start control threshold and close
Power amplifier standing wave alarmWhen the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off
Amplifier overcurrent alarmWhen the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off
Amplifier under-power alarmWhen the power amplifier detection power is less than 33dBm, an under-power alarm is displayed
Amplifier overvoltage alarmWhen the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down
Amplifier undervoltage alarmAmplifier voltage
Amplifier part query parametersAmplifier switch statusIf the power amplifier is set to"OFF", the query should be the state of power amplifier off state; otherwise, it is the open
power amplifier state
Downstream output power level valueDetect power amplifier output power value, detection range (Pomax+2, Pomax-20)Detection accuracy: Pout±1dB
Downward standing wave ratioThe standing wave is normally 1.2, when the load is mismatched, the query value is 4.0
temperature queryDetect the internal temperature of the module, detection range: -40℃~+100℃Detection error: ±3℃
ALC value queryThe displayed value is equal to the actual set ALC value
Voltage detectionDetection module working voltage
Current DetectionDetection module operating current
Signal generator settingsFrequency setting mode 1Any single frequency point setting within the rangeThe frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G
Frequency setting mode 2Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set
Frequency setting mode 3Set any 4 sub-frequency segments within the bandwidth, and the sub-segments are incremented
Module Communication ProtocolRS485
Interface definition+:28V,-: GND; 1:485A,2:485B