150W 5.75-5.9GHz DDS Integrated Power Amplifier Module Digital RF Modulator with ALC Controls
Equipped with software-adjustable power and three frequency-set modes, it also features comprehensive protection—high-temp shutdown (over 85℃), VSWR (over 4) auto-shutdown, over-current (over 12A) and under-voltage alarms. Real-time status is visible via LCD (frequency/power/switching) and three LEDs (POWER/RUN/ALARM). With internal fan cooling, the 156x122x58mm, ≤1600g module suits stand-alone or portable use.
Frequency Range | 5.75-5.9GHz | |
Inpedances | 50Ω | |
Operating Voltage | 28-36V, (32V typ) | |
Operating Current | ≤13A (150W typ) | |
Controllable Output Power | 150W (Software set power level) | |
ALC Power Adjustment Range | ≥10dB (Voltage controlled attenuation) | |
Inband Ripple | ≤2.5dB (Peak) | |
Max. Allowable Input Power | ≤+10dBm (Duration 1 min without damage) | |
Input/Output VSWR | 1.5:1 (Add +32V, standard network) | |
LCD Liquid-crystal Display | Display frequency, power, switching | |
With 3 LEDS | POWER: power indication RUN: running indication ALARM: alarm indication | |
Appearance (Usage) | Black integerated module with fan (for stand-alone or portable use) | |
Amplifier Swith | Turn the amplifier on or off | |
Alarm Swith | Turning on and blocking alarms | |
Downstream Power Control | Software adjustable output power, adjustable range≥10dB | |
Power off Temperature Alarm | High-temperature amplifier shutdown threshold can be set, amplfier temperature exceeds 85 degrees, automatic shutdown; 65 degrees automatic recovery | |
Amplifier Power Alarm | The actual power value is 2 dB above the downstream AlC start control threshold off | |
Amplifier VSWR Alarm | Amphfer VSWR over than 4, ampifier auto shutdown | |
Power over Flow Alarm | Amplfier detects current over 12A, and the ampifier automatically shuts down. | |
Amplifier Under Power Alarm | The ampifier detected power is less than 37dBm | |
Power Under Voltage Alarm | Amplifier voltage more than 32V, or less than 20V | |
Amplifier Switch Status | If the ampifier is set to"OFF", the query should be off amplifier status; otherwise, it is on amplifier | |
Downstream VSWR | Connected to VSWR normal 1.2, mismatched load, the query value of 4.0 | |
Temperature Search | Detect the internal temperature of the module, detection range: -40℃-+100℃, detection error:±3℃ | |
Detection and Alarm | Voltage and current: detecting module operating voltage, operating current and alarms | |
Frequency Setting Mode 1 | Any single frequency point setting within the range | |
Frequency Setting Mode 2 | Set wideband sweep frequency mode, frequency, interval, step and other para meters can be set; Frequency setting accuracy 1M; Frequency maximum bandwidth up to 500M | |
Frequency Setting Mode 3 | Set any 4 sub-frequency bands within the bandwidth, single sub-band should be incremented up to 6G | |
RF Connector | TYPE N [F] | |
Power Supply Connector | D-Sub 7W2 | |
Control Connector | J30J-9ZKP | |
Dimension | 156x122x58mm(LxWxH) (tolerance:±0.5) | |
Weight | ≤1600g | |
Finishing | Alloy iridite | |
Temperature | Operating: -25℃- +85℃ | |
Heat Dissipation | Internal Fan | |
Environmental | N/A | |
| Note | 1. Low temperature can start, monitoring work. 2. Altitude, vibration and shock are designed with considerations, but without tests and experiments. | |