Dual Band Power Amplifier and Signal Generator Module Customized Frequency and Power DDS ALC RACK Version with Touch Screen
ZD-1UDPA-2.4/5.8G-100W
This rack-mounted dual-band power amplifier and signal generator module ,the operating frequency covers 2400 - 2500M and 5725 - 5850M, the power is 100W, the voltage is 28V, and the conversion efficiency is ≥42% (at 100W). The output power of 10W - 100W can be set by software, the ALC power adjustment range is ≥20dB, the gain is 50±1.0dB, the in-band fluctuation is ≤2.5dB, and the spurious emission is well controlled. It has rich monitoring functions, and can set parameters such as amplifier switch and alarm, and can detect power, standing wave ratio, temperature, etc. in real time. Through RS485 communication, there are three frequency setting modes, and the touch screen is easy to operate, providing stable and reliable signal processing capabilities for jammer applications.
Quantity:
This high-performance100W dual band power amplifierwith integratedsignal generator moduleis a professional RF solution designed for communication and electronic systems. Covering 2400-2500MHz/5725-5850MHz dual bands, this100W dual band power amplifierdelivers 50±1.0dB gain, ≤2.5dB in-band fluctuation, and 10W~100W software-adjustable output power, with ≥20dB ALC power adjustment range for stable signal output.
As aRACK DDS ALC versionrack-mounted unit with a touch screen, it integrates DDS and ALC technologies, featuring excellent spurious emissions control and wide -10~+65℃ operating temperature range. Equipped with comprehensive monitoring functions (over-temperature, over-power, over-current, over-voltage alarms, real-time power detection), thissignal generator moduleintegrated amplifier ensures reliable operation. With 28V operating voltage, N-Female RF connector, and RS485 interface, it is ideal for multi-band RF systems, communication relays, and electronic countermeasures, providing flexible, efficient, and intelligent RF amplification solutions.
| Item | Parameter | Remark | |||
| working frequency | 2400-2500M/5725-5850M | ||||
| power | 100W | ||||
| Operating Voltage | 28V | 24-36V | |||
| Conversion efficiency | ≥42% | @100W | |||
| Adjustable output power | 10W~100W | Software set power | |||
| ALC power adjustment range | ≥20dB | Voltage Controlled Attenuation | |||
| gain | 50±1.0dB | ||||
| In-band fluctuation | ≤2.5dB | peak | |||
| spurious emissions | In working band | ≤-15dBm/1MHz | Measured when the center frequency plus CW signal to the maximum output power | ||
| Out-of-band | 9KHz~1GHz | No higher than normal noise floor clutter | |||
| 1G~12.75GHz | |||||
| Maximum allowable input power | ≥+10dBm | Lasts 1min without damage | |||
| Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | |||
| Output VSWR | ≤1.35 | No power, standard network output -10dBm | |||
| ≤1.35 | Power On, Dual Directional Coupler Test | ||||
| High and low temperature test | Working environment temperature (℃) | -10~+65℃ | Low temperature can start, monitoring works normally | ||
| Gain Stability | ±1.5dB @-40℃~+65℃ | ||||
| power stability | ±1dB @-40℃~+65℃ | ||||
| Power Requirements | ≥8.5A @+28Vdc; | CW output 100W | |||
| Power supply interface, communication interface RS485 | 7W2 | Male, 1:485A; 2:485B | |||
| RF output connector | N-Female connector | ||||
| with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | ||||
| physical dimension | |||||
| weight | |||||
| Appearance (how to use) | Signal source power amplifier integrated module (fixed on the radiator) | ||||
| Monitoring Function | Description | Remark | |
| Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
| Alarm switch | Enable and disable the alarm function | ||
| Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
| Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
| Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
| Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
| Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
| Amplifier under-power alarm | When the power amplifier detection power is less than 33dBm, an under-power alarm is displayed | ||
| Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
| Amplifier undervoltage alarm | Amplifier voltage | ||
| Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to"OFF", the query should be the state of power amplifier off state; otherwise, it is the open power amplifier state | |
| Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy: Pout±1dB | |
| Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
| temperature query | Detect the internal temperature of the module, detection range: -40℃~+100℃ | Detection error: ±3℃ | |
| ALC value query | The displayed value is equal to the actual set ALC value | ||
| Voltage detection | Detection module working voltage | ||
| Current Detection | Detection module operating current | ||
| Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
| Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
| Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and the sub-segments are incremented | ||
| Module Communication Protocol | RS485 | ||
| Interface definition | +:28V,-: GND; 1:485A,2:485B | ||