Ultra Wideband 20-6000MHz 100W Power Amplifier with DDS Signal Generator
ZD-DPA-X/XM-100W
This high-performance ultra wideband power amplifier delivers 100W output power across an exceptionally wide 20-6000MHz frequency range, making it ideal for military, aerospace, and advanced RF testing applications. The integrated DDS Direct Digital Synthesis signal generator ensures precise frequency control, allowing users to generate stable, low-phase-noise signals with programmable modulation for complex signal scenarios. Engineered for reliability, the amplifier features high efficiency ≥42% and software-adjustable power levels 10W-100W, with an ALC Automatic Level Control range of ≥30dB for dynamic power management. Advanced thermal protection, including an active cooling system (heat sink + fan), ensures stable operation even under continuous high-power conditions. Additional features include real-time monitoring (power, temperature, VSWR, RS485 control interface, and comprehensive protection against overvoltage, overcurrent, and signal reflection VSWR ≤1.35. Compact and rugged, this ultra wideband amplifier is perfect for electronic warfare, signal jamming, and wideband communication systems requiring both high power and precision frequency synthesis.
Quantity:
| Item | Parameter | Remark | |||
| working frequency | 20M-6000M | ||||
| power | 100W | ||||
| Operating Voltage | 28V | 24-36V | |||
| Conversion efficiency | ≥42% | @100W | |||
| Adjustable output power | 10W~100W | Software set power | |||
| ALC power adjustment range | ≥20dB | Voltage Controlled Attenuation | |||
| gain | 48±1.0dB | ||||
| In-band fluctuation | ≤2.5dB | peak | |||
| spurious emissions | In working band | ≤-15dBm/1MHz | Measured when the center frequency plus CW signal to the maximum output power | ||
| Out-of-band | 9KHz~1GHz | No higher than normal noise floor clutter | |||
| 1G~12.75GHz | |||||
| Maximum allowable input power | ≥+10dBm | Lasts 1min without damage | |||
| Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | |||
| Output VSWR | ≤1.35 | No power, standard network output -10dBm | |||
| ≤1.35 | Power On, Dual Directional Coupler Test | ||||
| High and low temperature test | Working environment temperature (℃) | -10~+65℃ | Low temperature can start, monitoring works normally | ||
| Gain Stability | ±1.5dB @-40℃~+65℃ | ||||
| power stability | ±1dB @-40℃~+65℃ | ||||
| Power Requirements | ≥8A @+28Vdc; | CW output 100W | |||
| Power supply interface, communication interface RS485 | 7W2 | Male, 1:485A; 2:485B | |||
| RF output connector | N-Female connector | ||||
| with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | ||||
| physical dimension | 700M-6G:155*125*26mm; 20M-500M:155*125*35mm | ||||
| weight | |||||
| Appearance (how to use) | Signal source power amplifier integrated module (fixed on the radiator) | ||||
| Monitoring Function | Description | Remark | |
| Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
| Alarm switch | Enable and disable the alarm function | ||
| Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
| Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
| Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
| Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
| Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
| Amplifier under-power alarm | When the power amplifier detection power is less than 33dBm, an under-power alarm is displayed | ||
| Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
| Amplifier undervoltage alarm | Amplifier voltage | ||
| Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to"OFF", the query should be the state of power amplifier off state; otherwise, it is the open power amplifier state | |
| Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy: Pout±1dB | |
| Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
| temperature query | Detect the internal temperature of the module, detection range: -40℃~+100℃ | Detection error: ±3℃ | |
| ALC value query | The displayed value is equal to the actual set ALC value | ||
| Voltage detection | Detection module working voltage | ||
| Current Detection | Detection module operating current | ||
| Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
| Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
| Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and the sub-segments are incremented | ||
| Module Communication Protocol | RS485 | ||
| Interface definition | +:28V,-: GND; 1:485A,2:485B | ||