Ultra Wideband 600-6200MHz 100W Power Amplifier + DDS Signal Generator Integrated Module with Heat Sink and Cooling Fan
600 - 6200MHz Ultra Wideband Power Amplifier and (DDS Signal Generator) Integrated Module, Top Performance
In the field of modern communications and electronic testing, the demand for high-performance signal processing equipment is extremely urgent. Our Ultra wideband 600 - 6200MHz 100W power amplifier + DDS Signal generator integrated module with heat sink and cooling fan is a leader in the industry.
As a device that integrates power amplifier and DDS - generator, it perfectly combines power amplification and signal generation functions. Its ultra-wideband characteristics, covering the 600 - 6200MHz frequency band, are excellent wide band signal generator and signal source. Whether it is precision testing in scientific research institutions or signal optimization in communication companies, it can easily handle it.
As an RF module, it is not only an ultra wideband power amplifier, but also a stable and reliable 700 - 6000MHz power amplifier. It can achieve 10W - 100W controllable output power, gain of 50±1.0dB, and in-band fluctuation ≤2.5dB, ensuring accurate and stable signal amplification. Built-in heat sink and cooling fan ensure stable operation in -10~ +65℃ environment.
Rich monitoring and control functions, such as over-temperature, over-current, standing wave ratio and other alarm mechanisms, as well as convenient parameter query and setting, provide users with all-round use protection. Choosing this integrated module means choosing advanced technology and excellent performance, providing a one-stop solution for your signal processing needs.
Item | Parameter | Unit | Remarks | |||
Operating Voltage | 28 | V | 24-30V | |||
Conversion efficiency | ≥42% | % | @100W typical | |||
Controllable output power | 10W~100W | W | Software set power level | |||
ALC power adjustment range | ≥30 | dB | Voltage Controlled Attenuation | |||
gain | 50±1.0 | dB | ||||
In-band fluctuation | ≤2.5 | dB | peak-to-peak | |||
spurious emission | In working band | ≤-15dBm/1MHz | dBm | Measured when the center frequency plus CW signal to the maximum output power | ||
out of work band | 9KHz~1GHz | No higher than normal noise floor clutter | dBm | |||
1G~12.75GHz | dBm | |||||
Maximum allowable input power | ≥+10dBm | dBm | Lasts 1min without damage | |||
Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | ||||
Output VSWR | ≤1.30 | No power, standard network output -10dBm | ||||
≤1.35 | Power On, Dual Directional Coupler Test | |||||
High and low temperature test | Working ambient temperature (℃) | -10~+65 | ℃ | Low temperature can start, monitoring works normally | ||
Gain Stability | ±1.5 @-40℃~+65℃ | dB | ||||
power stability | ±1 @-40℃~+65℃ | dB | ||||
Power Requirements | ≥8A @+28Vdc | CW output 100W | ||||
Power supply interface, monitoring interface RS485 | 7W2 | Male | ||||
RF output connector | N-F connector | |||||
LCD liquid crystal display | Display frequency, power, switch status | |||||
with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | |||||
Built-in cooling fan | Modules can be run separately | |||||
physical dimension | 255x165x80mm | |||||
Weight | 3.5Kg | |||||
Appearance (how to use) | Green integrated module with fan (single or portable use) | |||||
2. Module software settings
Monitoring | Function Description | Remarks | |
Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
Alarm switch | Enable and disable the alarm function | ||
Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
Amplifier under-power alarm | When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed | ||
Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to"OFF", the query should be the state of the power amplifier off; otherwise, the state of the power amplifier will be turned on. | |
Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy:Pout±1dB | |
Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
temperature query | Detect the internal temperature of the module, detection range: -40℃~+100℃ | detection error:±3℃ | |
ALC value query | The displayed value is equal to the actual set ALC value | ||
Voltage detection | Detection module working voltage | ||
Current Detection | Detection module operating current | ||
Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is100M, and the maximum is 6G |
Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented | ||
module communication | RS485 | ||
Interface definition | +:28V,-: GND; control bit 1:485A,2:485B | ||