4 Band Full Frequency 300-6000MHz Ultra Wide Band Touch Screen RACK Version Power Amplifier with DDS ALC
ZD-DPA-300/6000M-100W
This rack-mounted 4-band full-frequency 300–6000MHz ultra-wideband power amplifier and signal generator module is professionally customized for secure facility management, spectrum control, and critical signal management scenarios. It supports customizable frequency and power configurations with 1 to 4 adjustable bands, equipped with an ALC automatic leveling function.
Operating at 28V, it features a conversion efficiency of ≥42% at 100W, with output power adjustable from 10W to 100W, gain of 50±1.0dB, in-band flatness ≤2.5dB, and excellent spurious emission suppression.
The unit integrates a touchscreen control panel and RS485 communication, offering comprehensive real-time monitoring including output power, VSWR, and temperature. It supports parameter settings such as module enable and alarm thresholds, providing stable and reliable signal amplification and generation for demanding spectrum management applications.
Operating at 28V, it features a conversion efficiency of ≥42% at 100W, with output power adjustable from 10W to 100W, gain of 50±1.0dB, in-band flatness ≤2.5dB, and excellent spurious emission suppression.
The unit integrates a touchscreen control panel and RS485 communication, offering comprehensive real-time monitoring including output power, VSWR, and temperature. It supports parameter settings such as module enable and alarm thresholds, providing stable and reliable signal amplification and generation for demanding spectrum management applications.
Quantity:
Full frequency coverage delivers efficient signal management solutions. In key areas including secure facilities and public safety zones, precise and stable signal control is essential. Our 4‑band full‑frequency 300–6000MHz ultra‑wideband module acts as a highly reliable solution for communication regulation.
As aHigh power amplifier module 1U RACK, it features a compact 1U design for easy integration and deployment. Equipped with aDDS function signal generator, it covers 300–6000MHz and supports customizable frequency and power. TheDDS signal generator moduleworks with theradio frequency signal generatorto ensure stable and accurate signal output.
Controlled via touchscreen and RS485, it provides complete monitoring and parameter setup. With 50±1.0dB gain, low in-band fluctuation and excellent spurious suppression, this integrated solution withradio frequency signal generatoreffectively standardizes signal transmission and safeguards key environments.
| Item | Parameter | Remark | |||
| working frequency | customizable | ||||
| power | 100W | ||||
| Operating Voltage | 28V | 24-36V | |||
| Conversion efficiency | ≥42% | @100W | |||
| Adjustable output power | 10W~100W | Software set power | |||
| ALC power adjustment range | ≥20dB | Voltage Controlled Attenuation | |||
| gain | 50±1.0dB | ||||
| In-band fluctuation | ≤2.5dB | peak | |||
| spurious emissions | In working band | ≤-15dBm/1MHz | Measured when the center frequency plus CW signal to the maximum output power | ||
| Out-of-band | 9KHz~1GHz | No higher than normal noise floor clutter | |||
| 1G~12.75GHz | |||||
| Maximum allowable input power | ≥+10dBm | Lasts 1min without damage | |||
| Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | |||
| Output VSWR | ≤1.35 | No power, standard network output -10dBm | |||
| ≤1.35 | Power On, Dual Directional Coupler Test | ||||
| High and low temperature test | Working environment temperature (℃) | -10~+65℃ | Low temperature can start, monitoring works normally | ||
| Gain Stability | ±1.5dB @-40℃~+65℃ | ||||
| power stability | ±1dB @-40℃~+65℃ | ||||
| Power Requirements | ≥8.5A @+28Vdc; | CW output 100W | |||
| Power supply interface, communication interface RS485 | 7W2 | Male, 1:485A; 2:485B | |||
| RF output connector | N-Female connector | ||||
| with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | ||||
| physical dimension | |||||
| weight | |||||
| Appearance (how to use) | Signal source power amplifier integrated module (fixed on the radiator) | ||||
| Monitoring Function | Description | Remark | |
| Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
| Alarm switch | Enable and disable the alarm function | ||
| Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
| Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
| Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
| Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
| Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
| Amplifier under-power alarm | When the power amplifier detection power is less than 33dBm, an under-power alarm is displayed | ||
| Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
| Amplifier undervoltage alarm | Amplifier voltage | ||
| Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to"OFF", the query should be the state of power amplifier off state; otherwise, it is the open power amplifier state | |
| Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy: Pout±1dB | |
| Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
| temperature query | Detect the internal temperature of the module, detection range: -40℃~+100℃ | Detection error: ±3℃ | |
| ALC value query | The displayed value is equal to the actual set ALC value | ||
| Voltage detection | Detection module working voltage | ||
| Current Detection | Detection module operating current | ||
| Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
| Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
| Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and the sub-segments are incremented | ||
| Module Communication Protocol | RS485 | ||
| Interface definition | +:28V,-: GND; 1:485A,2:485B | ||